Welcome to KillTest.com

TOP Exams

Want to practice some free Network Appliance NS0-592 exam questions? You can study the following Network Appliance NS0-592 exam online questions. Killtest provides 65 Q&As for Network Appliance NS0-592 exam, which has been proven effective in the NS0-592 exam preparation. Besides, you can get full payment fee refund if you fail NS0-592 exam by using Killtest NS0-592 practice exam questions. Ready? Go!

 Get NS0-592 with 65 Q&As

Network Appliance NS0-592 Online Practice Exam Questions

The questions of NS0-592 were last updated on Apr 18,2024 .

Viewing page 1 out of 4 pages.

Viewing questions 1 out of 20 questions

Question#1

Click the exhibit button.

文本, 电子邮件

描述已自动生成

The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit.
What is the reason for this error?

A. The requested OU Secure does not exist in the Active Directory and must be created by the Active Directory administrator.
B. The requested OU Secure has incorrect principal and errored with KRB5KDC_ERR_S_PRINCIPAL_UNKNOW
C. The administrator account password used in vserver cifs create was not entered correctly.
D. The syntax is incorrect; it should be vserver cifs create -cifs-server svm1 -domain example.com -ou ou=Secure, dc=example, dc=com.

Question#2

Click the exhibit button.

图形用户界面

低可信度描述已自动生成

Your customer is calling about their MetroCluster environment. They have provided you with the output of the metrocluster interconnect adapter show command.
Referring to the exhibit, which statement is correct?

A. For all MetroCluster configurations, this is expected output.
B. The InfiniBand cables should be connected in this configuration.
C. The InfiniBand interconnect is not used in MetroCluster.
D. This is a 2-node MetroCluster.

Question#3

You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.
When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day.
You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid. resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.
You have four separate ISLs between your data centers using Brocade 6510 switches.
Hardware problems are not an issue.
Which two actions should you take to prevent this problem in the future? (Choose two.)

A. Update to at least ONTAP 9.4 software.
B. Restart the resynchronizations after modifying storage raid-options modify raid.resync.num_concurrent_ios_per_rg command.
C. Avoid changes on your aggregates during the maintenance window.
D. Take the corresponding plexes offline before maintenance to avoid a base-level synchronization.

Question#4

Click the exhibit button.



When you log in to a node, a warning is displayed as shown in the exhibit.
Which statement is correct in this scenario?

A. The node root volume was moved to a new aggregate.
B. The partner still hosts the CFO aggregate for the node.
C. One or more RDB db files are damaged due to an internal software error.
D. The node cannot communicate with the rest of the nodes in the cluster.

Question#5

Click the exhibit button.

文本

描述已自动生成

A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.
Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

A. Review the LIF configuration on the cluster.
B. Review the driver version on the server.
C. Review that the host side FC link ports are enabled.
D. Review the igroup configuration on the cluster.

Exam Code: NS0-592
Q & A: 65 Q&As
Updated:  Apr 18,2024

 Get NS0-592 Full Version

KILLTEST CONTACT INFO

[email protected]

GMT+8: Mon-Sat 8:00-18:00

GMT: Mon-Sat 0:00-10:00