Welcome to KillTest.com

VMware VCAP-NV Design 2021 3V0-42.20 Practice Exam Updated | Killtest 2021

Mar 24,2021

VMware VCAP-NV Design 2021 3V0-42.20 practice exam has been updated, which will be valid for you to pass this Advanced Design VMware NSX-T Data Center 3V0-42.20 exam. Advanced Design NSX-T Data Center 3.0 3V0-42.20 exam tests your ability to gather customer requirements, risks, constraints, and assumptions, and use that information to make design recommendations for NSX-T Data Center 3.0 solutions. Killtest new updated VMware VCAP-NV Design 2021 3V0-42.20 practice exam can ensure you pass the VMware VCAP-NV Design 2021 3V0-42.20 exam. 

 

VMware VCAP-NV Design 2021 3V0-42.20 Practice Exam Updated

 

VMware VCAP-NV Design 2021 3V0-42.20 Exam


Show you the basic Advanced Design VMware NSX-T Data Center 3V0-42.20 exam information in the following table. 

 Number of Questions  57
 Duration  105 minutes
 Passing Score  300
 Format  Single and Multiple Choice, Proctored
 Language  English
 Price  $450

3V0-42.20 Advanced Design VMware NSX-T Data Center Exam Objectives


VMware exam blueprint sections are now standardized to the seven sections below.
3V0-42.20 Exam Topics
New updated Advanced Design VMware NSX-T Data Center 3V0-42.20 practice exam from Killtest can help you study the above VMware VCAP-NV Design 2021 3V0-42.20 exam objectives well. List some VMware certification 3V0-42.20 exam updated demo practice questions below. 

Which selection must be taken into consideration when creating a Logical Design for a planned migration? (Choose the best answer.)
A. An N-VDS can only attach to a single Overlay transport zone.
B. An N-VDS can only attach to a single VLAN transport zone.
C. An N-VDS can attach to both an Overlay and a VLAN transport zone to a N-VDS having different name/s.
D. An N-VDS must be disabled before attaching both Overlay and VLAN transport zones.
Answer: B

Which three assessment findings are part of a Conceptual Design? (Choose three.)
A. risks
B. host names
C. justifications
D. constraints
E. assumptions
F. vendor model
Answer: ACD

An administrator is asked to improve Recovery Point Objective (RPO) and Recovery Time Objective (RTO) for Disaster Recovery (DR) in their company network. The network has a primary site and a secondary site. The ability to support outages with minimum loss of connectivity to the company’s core application is a priority. Which design should the administrator recommend? (Choose the best answer.)
A. NSX-T Data Center using an Orchestrator to recover VMs across sites.
B. NSX-T Data Center using Federation and dependencies set between primary and secondary sites.
C. NSX-T Data Center using a registered third-party DR solution.
D. NSX-T Data Center using built-in standard automation DR and secondary site recovery setup.
Answer: B

A telecom company has purchased NSX-T as part of a Software Defined Data Center (SDDC) initiative. The company wants to ensure the highest performance for network traffic leaving the virtual environment. Which two selections would an architect recommend to achieve the customer’s goal? (Choose two.)
A. Configure Equal-Cost Multi-Pathing on the NSX Edges.
B. Configure SR-IOV for the virtual NSX Edges.
C. Use bare metal NSX Edges.
D. Select Network cards that support VXLAN Offload.
E. Set “Latency Sensitive” option to High when deploying the virtual NSX Edges.
Answer: BE

Which three choices are non-functional requirements? (Choose three.)
A. authorization
B. certification
C. availability
D. authentication
E. scalability
F. cost
Answer: ABE

0 belongs to any of them

Submit Reviews

Your content: 
Your name:  Verify Code:  feedback    
3V0-42.20 Practice Exam Q&A: 57 Updated: April 18,2024

Releated Certifications

VCAP-NV Design 2020

KILLTEST CONTACT INFO

[email protected]

GMT+8: Mon-Sat 8:00-18:00

GMT: Mon-Sat 0:00-10:00